VSMeasy - Molded Busbars
for Wiring of Power Contactors

FTG offers a wide range of accessories for wiring motor contactors or mini contactors in plant and control engineering. The fully molded busbars and star-point bridges are used to reduce errors in wiring connection of power contactors. The busbars fit to the devices such as from ABB, Allen Bradley, Eaton, GE, Lovato, Schneider Electric, Siemens or WEG.

Suitable for the following contactors / mini contactor manufacturers

ABB also offers a large number of three-pole contactors to which the fully molded busbars fit.
WK11: B6; B7; AS09; AS12; AS16
WK21: AF09-30; AF12-30; AF16-30;
WK51: AF09-30; AF12-30; AF16-30; AF26-30; AF30-30;
WK12: B6; B7; AS09 – AS16
WK22: AF09-30 – AF30-30

FTG offers a variety of busbars for connecting the standard contactors (100-C) and miniature contactors (100-M) from Allen Bradley (Rockwell Automation).
WK11: 100-M05N; 100-M09N
WK21: 100-C09; 100-C12; 100-C16; 100-C23
WK41: 100-C30; 100C37
WK12: 100-M05N – 100-M09N
WK22: 100-C09 – 100-C23

Suitable Eaton or Moeller devices for the following contactor wiring:
WK11: DIL EM; DILM7; DILM12; DILM15
WK21: DIL 00M; DIL 00AM
WK41: DIL 0
WK51: DIL 00M – DIL 00AM
WK12: DIL EM; DILM7; DILM12; DILM15
WK22: DIL 00M – DIL 00AM
WK42: DIL0M– DIL 0 AM
WK13: DIL EEM– EM 12/DILM 7– DILM 12– DILM 15
WK23: DIL 00M– DIL 0 AM | ABB A9– A12– A18
WK43: DIL0M– DIL 0 AM

The busbars for GE contactors, so called Power Controls:
WK11: LS07; MC0; MC1
WK41: CL25
WK51: CL00; CL01; CL02
WK12: LS07
WK22: CL00; CL01; CL02
WK13: LS07

Reversing or star-delta wiring for contactors from Lovato:
WK11: BG06; BG09; BG12
WK21: BF09; BF12; BF16
WK41: BF26; BF32; BF38
WK51: BF09; BF12; BF16
WK12: BG06 – BG12
WK22: BF09 – BF16

Busbars for contactors of Schneider Electric:
WK11: LC1-K07 – LC1K12
WK41: LC1-D09 – LC1-D38
WK12: LC1-K07 – LC1-K12
WK42: LC1– D09 bis LC1– D38
WK13: LC1– K07– LC1– K12
WK23: LC1– D09 bis – LC1– D18
WK43: LC1– D09 bis LC1– D38

The following busbars are suitable for wiring power contactors from Siemens:
WK11: 3RT2015 – 3RT2017
WK41: 3RT1023-3RT1026
WK12: 3RT1015 – 3RT1017
WK42: 3RT1024– 3RT1026
WK13: 3RT1015– 3RT1017
WK43: 3RT1024– 3RT1026

FTG also offers simple busbars for the standard contactors from WEG:
WK11: CW07; CWC07
WK21: CWM9 – CWM18
WK41: CWM25
WK51: CWM9 – CWM18
WK12: CW07; CWC07
WK22: CWM9 – CWM18
WK42: CWM25
WK13: CW07 / CWC07 bis CWC016
WK23: CWM9– CWM12– CWM18
WK43: CWM25

 

Reversing Busbar Wiring Kit U=690V | I=16A

Reversed Wiring

Reversing wiring is used to wire power contactors that contain a reversing contactor circuit that regulate the direction of rotation of the three-phase motor.

for mini contactors P= 2,2 – 4kW
Module width 45mm, five terminals
U=690V | I=16A | IEC 947

Contactor Manufacturer:
Allen Bradley: 100-M05N, 100-M09N
Schneider: LC1-K07, LC1-K09, LC1-K12
Siemens: 3RT1015, 3RT1016, 3RT1017
Eaton (Moeller): DIL EM, DILM7, DILM12, DILM15
Lovato: BG06, BG09, BG12
GE. Power Controls: LS07, MC0, MC1
ABB: B6, B7, AS09, AS12, AS16
WEG: CW07, CWC07

Contactors P= 4-7.5kW
Module width 45mm, four terminals
Ue =690V | Iu =25A | IEC 947

Contactor manufacturers:
Allen Bradley: 100-C09, 100-C12, 100-C16, 100-C23
Eaton (Moeller): DIL 00M – DIL 00AM
Lovato: BF09, BF12, BF16
GE. Power Controls: CL00, CL01, CL02
ABB: AF09-30, AF12-30, AF16-30, AF26-30, AF30-30
WEG: CWM9 – CWM18

Contactors P=11 – 15kW
Module width
45mm, three terminals
U=690V | I=40A | IEC 947

Contactor manufacturers:
Allen Bradley: 100-C30, 100-C37
Schneider: LC1-D09 – LC1-D38
Siemens: 3RT1023, 3RT1024, 3RT1025, 3RT26
Eaton (Moeller): DIL 0
Lovato: BF26, BF32, BF38
GE. Power Controls: CL25
WEG: CWM25

Contactors P = 4 – 7,5 kW
Module width 45mm, four terminals
Ue =690V |
Iu =25A | IEC 947

With mechanical interlock (9/15 mm)

Contactor manufacturers: 
Allen Bradley: 100-C09,100-C12, 100-C16, 100-C23
Eaton (Moeller): DIL 00M – DIL 00AM
Lovato: BF09, BF12, BF16
GE. Power Controls: CL 00, CL01, CL02
ABB: AF09-30, AF12-30, AF16-30, AF26 -30, AF30-30
WEG: CWM9 – CWM18

Star-Delta-Wiring System U=690V | I=16A

Star-Delta-Wiring

For motors with a star-delta connection, the starter current is first throttled and then started up with the delta connection.

Mini-Contactors P=2,2 – 4kW
Module width: 45mm, five terminals
U
=690V | I=16A | IEC 947

Manufacturer of Mini-Contactors:
Allen 
Bradley: 100-M05N – 100-M09N
Schneider: LC1-K07 – LC1-K12

Siemens: 3RT1015 – 3RT1017

Eaton (Moeller): DIL EM, 
DILM7, DILM12, DILM15
Lovato: BG06 – BG12

GE. Power Controls: LS07, MC0, MC1

ABB: B6, B7, AS09 – AS16

WEG: CW07, CWC07

Contactors P=4 – 7.5kW
Module width
45mm, four terminals
U=690V | I=25A | IEC 947

Manufacturer of Contactors:
Allen Bradley: 100-C09 – 100-C23
Eaton (Moeller): DIL 00M – DIL 00AM
Lovato: BF09 – BF16
GE. Power Controls: CL00, 01, 02
ABB: AF09-30 – AF30-30
WEG: CWM9 – CWM18

Contactors P=11 – 15kW
Module width
45mm, three terminals
U=690V | I=40A | IEC 947

Manufacturer of Contactors:
Allen Bradley: 100-C30, 100-C37
Schneider: LC1-D09 – LC1-D38
Siemens: 3RT1023 – 3RT1026
Eaton (Moeller): DIL 0
Lovato: BF26 – BF38
GE. Power Controls: CL25
WEG: CWM25

Contactors P=4 – 7,5kW
Module width
45mm, four terminals
with mechanical interlock (9/15mm)
U=690V | I=25A | IEC 947

Manufacturer of Contactors:
Allen Bradley: 100-C09 – 100-C23
Eaton (Moeller): DIL 00M – DIL 00AM
Lovato: BF09 – BF16
GE. Power Controls: CL 00, 01, 02
ABB: AF09-30 – AF30-30
WEG: CWM9 – CWM18

Parallel Wiring U=690V | I=16-40A

Parallel Wiring

With the parallel wiring of contactors, the current carrying capacity can be increased if necessary.

Mini-Contactors P=2,2 – 4kW
Module width: 45mm, five terminals
U
=690V | I=16A | IEC 947


Contactor Manufacturer:
Allen Bradley: 100-M05N – 100-M09N
Schneider: LC1-K07 – LC1- K12
Siemens: 3RT1015 – 3RT1017
Eaton (Moeller): DIL EM, DILM7, DILM12, DILM15
Lovato: BG06 – BG12
GE. Power Controls: LS07, MC0, MC1
ABB: B6, B7, AS09 – AS16
WEG: CW07, CWC07

Contactors P=4 – 7.5kW
Module width: 45mm, four terminals
Ue =690V | Iu =25A | IEC 947

Contactor Manufacturer:
Allen Bradley: 100-C09 – 100-C23
Eaton (Moeller): DIL 00M – DIL 00AM
Lovato: BF09 – BF16
GE. Power Controls: CL00, 01, 02
ABB: AF09-30 – AF30-30
WEG: CWM9 – CWM18

Contactors P=11 – 15kW
Module width: 45mm, three terminals
Ue =690V | Iu =40A | IEC 947

Contactor Manufacturer:
Allen Bradley: 100-C30 – 100-C37
Schneider: LC1-D09 – LC1-D38
Siemens: 3RT1023 – 3RT1026
Eaton (Moeller): DIL 0
Lovato: BF26 – BF38
GE. Power Controls: CL25
WEG: CWM25

Star-Point-Bridge U=690V | I=16-40A

Star-Point-Bridge

The star-point bridge is used to implement a star connection via a contactor.

Mini-Contactor P=2,2 – 4 kW
Module width:
45mm
Ue =690V | Iu =16A | IEC 947

Mini-Contactor Manufacturer:
Allen Bradley: 100-M05N, M09N
Schneider: LC1-K07 – LC1-K12
Siemens: 3RT1015 – 3RT1017
Eaton (Moeller): DIL EM, DILM7, DILM12, DILM15
Lovato: BG06 – BG12
GE. Power Controls: LS07, MC0, MC1
ABB: B6, B7, AS09 – AS16
WEG: CW07, CWC07

Contactors P=4 – 7.5 kW
Module width
45mm
U=690V | Iu=25A | IEC 947

Contactor Manufacturer:
Allen Bradley: 100-C09 – 100-C23
Eaton (Moeller): DIL 00M – DIL 00AM
Lovato: BF09 – BF16
GE. Power Controls: CL00, 01, 02
ABB: AF09 -30 – AF30-30
WEG: CWM9 – CWM18

Contactors P=11 – 15 kW
Module width
45mm
U=690V | Iu =40A | IEC 947

Contactor Manufacturer:
Allen Bradley: 100-C30, C37
Schneider: LC1-D09 – LC1-D38
Siemens: 3RT1023 – 3RT1026
Eaton (Moeller): DIL 0
Lovato: BF26 – BF38
GE. Power Controls: CL25
WEG: CWM25

Additional components for contactor wiring and for motor protection switches

CMI Busbars for parallel wiring

Contactor wiring in connection with a motor protection switch and an feed-in block can be quickly implemented using CMI busbars.

UL508

600V AC | Imax =34A
IEC/EN 60947-4-1
Ue =690 V | Uimp =6kV | Ith =34 A 

Manufacturer mini contactors:
Eaton (Moeller): DILM 7, DILM 12, DILM 15

UL508

600V AC | Imax =34A
IEC/EN 60947-4-1
Ue =690 V | Uimp =6kV | Ith =34 A 

Manufacturer mini contactors:
Eaton (Moeller): DILM 7, DILM 12, DILM 15

UL508

600V AC | Imax =34A
IEC/EN 60947-4-1
Ue =690 V | Uimp =6kV | Ith =34 A 

Manufacturer mini contactors:
Eaton (Moeller): DILM 7, DILM 12, DILM 15

 UL508

600V AC | Imax=34A | IEC/EN 60947-4-1
Ue=690 V | Uimp =6kV |Ith =34 A 

Manufacturer mini contactors:
Allen -Bradley: 100K
Schneider: LC1-K07, K09, K12
Siemens: 3R1015-3RT1017
Eaton (Moeller): DIL EM
GE. Power Controls: LS07
WEG: CW07/CWC07, CWC016

 UL508

600V AC | Imax=34A | IEC/EN 60947-4-1
Ue=690 V | Uimp =6kV |Ith =34 A 

Manufacturer mini contactors:
Allen -Bradley: 100K
Schneider: LC1-K07, K09, K12
Siemens: 3R1015-3RT1017
Eaton (Moeller): DIL EM
GE. Power Controls: LS07
WEG: CW07/CWC07, CWC016

Feed-in Block BMI 25ICM

For feed-in on motor protection switches in connection with CMI busbars for parallel wiring of contactors that are connected with relays, for motors with the same power.

Feed-in terminal block, that is used with CMI busbars.
For crossections of 1,5 – 25 mm²
Ue =690V | Iu =34A

Manufacturer mini contactors:
Eaton DILM 7/DILM 12/DILM 15

CPM Busbars for Motor Protection Switches

There is a wide range of CPM busbars (63A / 120A) for quick and easy connection of motor protection switches with module widths of 45mm (+ 9mm) and 54mm (+ 9mm). More information can be found in the brochure.

Product Information
Further information on the range of busbars and accessories for motor protection.

Request a qoute now!

Friedrich Göhringer Elektrotechnik GmbH
Gerwigstrasse 8
78098 Triberg, Germany

Phone: +49 (0) 7722-9636-0
Fax: +49 (0) 7722-9636-36
E-Mail: info@ftg-germany.de

Office hours:
Mon. - Thu. 7.00 – 16.00 Uhr
Fri. 7.00 – 15.00 Uhr

Product range of FTG

Contact

Friedrich Göhringer Elektrotechnik GmbH
Gerwigstrasse 8
78098 Triberg, Germany

Phone   +49 (0) 7722-9636-0
E-Mail   info@ftg-germany.de